Technical Specifications
• ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition
• Dimension: 300x290xh 89.5 mm, approx. 3.5 kg
• Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 6 channels + st map 1 channel
• Gain: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV
• Printing speed: 5, 12.5, 25, 50, 100 mm/s
• Sampling rate: Analysis - 500 s Digital - 8,000 s
• Filters:
AC (50/60 Hz, -20 dB or better)
Muscle (25~35 Hz, -3dB or better)
Base line drift (0.05, 0.1, 0.2 Hz, -3 dB or better)
Low pass filter: off, 40 Hz, 100 Hz, 150 Hz
• Display: 7" color TFT LCD display (800x480), 12 channels preview ID, HR, gain, speed, power status
• Monitor display: ID , date, sensitivity, speed, filter, form, rhythm lead
• User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu)
• Patient data: ID , name, age, sex, height, weight, smoke, race, department, room number, study...etc.
• Basic measurement: Heart rate (30~300 bpm, ± 3 bpm), PR/RR int., QRS dur., QT/QTc int., P-R-T axis, SV1/RV5/R+S amp.
• Recorder: T hermal print head, roll paper width: A 4/Letter 215 mm (8.5")length: A 4 297 mm (11.7") letter 279 mm (11") A4 report paper: 210x300 mm (8.5"x11")
• Resolution: Vertical: 8 dot/mm (0.125 mm pitch)
• Electrical:
Internal noise: 20 µV (p-p) max
Input impedance: =50 MO
Input voltage range: = ±5 mV
Common mode rejection: > 105 dB
DC offset voltage: = ±400 mV
Patient leakage current: < 10 µA
Frequency response: 0.05 ~200 Hz in 3 dB
Isolated defibrillation and ESU protected
• Signal quality control: Lead fault detection, signal saturation detection Pacemaker pulse detection
• ECG data storage: storage for 200 ECGs, built-in memory
• Power:
input: 100-240 V, 1.5-0.75 A, 50-60 Hz
output: 15 V, 4.2 A
• Battery (Li-Ion): Replaceable and rechargeable, lithium ion, 10.8V, 3250mA 6 hours of normal use or print 200 ECG pages (12 channel format at 25 mm/s and 10 mm/mV) Battery complete charge in 3 hours with power off
• Communication: PC connection with LAN, WiFi (option), USB flash drive, USB barcode scanner (option)
• Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC
Gyógyászati termékek vásárlása előtt annak kockázatairól kérdezze meg kezelőorvosát.
Kérjük hogy a vásárolt termék szakszerű használatának érdekében a használati útmutatót
olvassa el.
Egészségügyi, higiéniai okokból (45/2014. Korm. rendelet 29 § e) az intim testrésszel, izzadtsággal, testnedvvel, vérrel, nyállal, műtéti heggel érintkez(het)ő termék esetében nincs lehetőség elállásra. Ezek pl. a kompressziós termékek, harisnyák, matracok, párnák, huzatok, sérvkötők, mosdatással - tisztítással kapcsolatos eszközök, wc-k és -magasítók, pelenkák, talpbetétek, antidecubitus-, vérvételi eszközök, tesztcsíkok, stb.